Interface specification | ||
Series of products | HB-08-08□□-01□-□ | |
I/O port | I/O port (8 signals): M8 3-hole | I/O port (16 signals): M8 4-hole |
Electrical parameter | ||
Number of I/O channels | 8 channels | |
Number of signals | 8DI/DO | 16DI/DO |
Polarity | NPN、PNP | |
Supply voltage | DC24V(18~30V) | |
Power condition monitoring | 18~30V normal (green light), <18 or >30V abnormal (red light) | |
Current of supply | Max: 8A | |
Channel rated current | 1.1A | |
Short circuit and overload protection | Main circuit, branch circuit double overload protection, short circuit protection | |
Cable parameters | ||
Cable specification | 3*1.0mm²+8*0.34mm² | 3*1.0mm²+16*0.34mm² |
Cable outlet mode | Scattered wire | |
Cable outer material | PVC fixed type;PUR drag chain type | |
Cable outlet specification | 3m, 5m, other lengths can be customized | |
General data | ||
Shell material | PC+ABS | |
Protection class | IP67 | |
Temperature tolerance range | -20℃~70℃ | |
Storage temperature | -40℃~85℃ | |
Size (mm) | 142L×36W×20H |