5-Conductor Shielded Cable
➢ Cable size: 2×0.25mm²+2×0.5mm²
Configuration
Add Favorite
Technical Parameter
File Download
Recommended accessories


Product model
ModelDR-CAB-016-ADR-CAB-026-A
MaterialPVC/Fixed typePUR/Drag chain type
Cable specification3×0.25mm²+2×0.5mm²   screened wire(3×0.25mm²+AL)+2×0.5mm²+EB
Product description
JacketPVCPUR
Flame resistanceFT2FT2   vertical fire resistance test
Rated80℃  300V80℃  300V
Product structure
CompositionConductor A:3C*0.25mm²Conductor B:2C*0.5mm²Conductor A:3C*0.25mm²Conductor B:2C*0.5mm²
MaterialTinned soft copper wire TA23/0.12Tinned copper wire TA45/0.1232/0.10±0.00664/0.10±0.006
DiameterAbout 0.66mmAbout 0.94mmAbout 0.65mmAbout   0.92mm
Insulation materialPVCPVCSR-PVCSR-PVC
Insulation outer diameter1.20±0.05mm1.55±0.05mm1.20±0.051.60±0.05
Finished cable
Separator manualDuring the weaving process, a tin-plated soft   copper wire shielding wire is added. The weaving density is ≥ 85%.FillFill
Separator materialTinned soft copper wire TA0.10mmAluminum foilPaper
Earth---32/0.10±0.006mm(Bare stranded copper conductor)
Braid material---Tin-plated
Composition---16/8/0.2
Nominal thickness(mm)0.85mm0.90
Jacket outer diameter6.50±0.15mm7.00±0.20
Electric Characteristics
Max conductor resistanceBelow 89.7 Ω/kmBelow 39Ω/Km79≤Ω/km@20℃39≤Ω/km@20℃
Spark test ---3000Vac
Pressure test AC2000V (no abnormalities within 1 minute)2000Vac
Packing specification
Packing specification200m,500m,1000m